Special considerations for home circuit design and construction

1. The air conditioner of the cabinet machine walks 4 squares of separate circuit. The kitchen and the bathroom are each separated by a 4 square circuit. The lighting is a 2.5 square circuit. The ordinary socket is 1-2 2.5 square circuits. The 1.5 square wire is not used.

2. The separation distance between strong and weak electricity is more than 30CM, and the distance between strong electric pipe and heating pipe (sheet), hot water pipe and gas pipe is greater than 30CM;

3, the same room power, telephone, TV and other sockets should be at the same level (except in special circumstances), strictly follow the principle of the left zero right fire ground line, the ground line is best to use the yellow-green line specified by the national standard;

4, enter the box line tube with lock protection, the line box should be laid flat, no elbow, the bend should be hot-bent or spring-bending, the connection should be welded with PVC glue. Strictly follow the principle of threading after first pipe laying, the place where the top can not be buried is to be protected by square wax pipe, bare wire is prohibited, and the ceiling wire must be fixed;

5, weak electricity can not have a connector (TV cable to use a frequency divider), the network cable is strictly prohibited joints;

6. The tube must be protected by electric power. When the three sets of lines enter the same line box, a separate line box must be set up. Place a wire box in the place where the ceiling has a lamp position;

7. When the circuit project is completed, it is necessary to test all the sockets and lamp wires with electric bulbs. If the power is strong or weak, it must be carefully tested and pulled. Is it a live line? It is strictly forbidden to carry out the next process without testing;

8. After the acceptance, draw the accurate road map and pay it to the owner (it is best to take the photo to save).

Chipper Shredder

In the light of difference of the product operating functions, shredder can be divided into wood chipper and leaf chipper. The max working diameters of tree and wood shredder are both 45mm, according to the new GS standard. If you need to buy min shredder, pls choose the knife plate structure, rather than mute structure.